- Chamber head (fast response time)
- Flow and temperature signal
- Probe length 200 … 350 mm
- Measuring ranges 0 … 40 m/s to 0 … 90 m/s
- Pressure resistantup to 10 bar
The generation of compressed air is a cost-intensive process. Therefore it is worthwhile to optimize compressed air networks.
The precise and continuous analysis of the actual consumption of a compressed air system is the basis for its optimization. To this end, the operator must know the actual volume flows of the system, the distribution of compressed air in the network and ultimately also the volume flows during idle times - the leakage quantity. This data can be used to determine exactly where and which optimisation measures must be carried out.
The solution is the use of volume flow sensors.
All necessary data will be collected, like leakage rates, consumption and distribution to the various points of use (cost allocation). Thus the maintenance intervals can be also flexibly adapted to the actual system states.
- Packaging machines
- Injection molding machines
- Textile machines
- Pneumatic conveying systems
- Painting
- Installation of air tools
- Insulating materials
Accessories
Connection technology
| Description | Article-Number |
|---|---|
| Power supply unit: output 24 V / 1A DC, supply voltage 115/230 V AC (strip terminal) | 535 282 |
Mounting and fixing technology
| Description | Article-Number |
|---|---|
| Welding sleeve steel, G½, according to EN 10241, 5 pieces | 524 916 |
| Welding sleeve stainless steel, G½, EN 10241, 2 pieces | 524 882 |
| Probe ball value 1" inside thread, connection to flow sensor: ½" inside thread incl. plug and chain | 530 940 |
| Probe ball value 1 ¼" inside thread, connection to flow sensor: ½" inside thread incl. plug and chain | 530 941 |
| Probe ball value 1 ½" inside thread, connection to flow sensor: ½" inside thread incl. plug and chain | 530 942 |
| Probe ball value 2" inside thread, connection to flow sensor: ½" inside thread incl. plug and chain | 530 943 |
| Straight-run probe ball valve ¾" inside thread, with threaded adapter for ½" full-length screw connection | 532 355 |
| Welded socket, steel, outside thread ¾", 5 pieces | 531 200 |
| Welded socket, stainless steel, outside thread ¾", 2 pieces | 531 201 |
| Assembly kit for pipe assembly suitable for MD 10.010/10.015 including pipe clamps and collar for adjustment to pipe diameter | 531 394 |
Measured value display
| Description | Article-Number |
|---|---|
| SCHMIDT® LED display MD 10.010 in wall housing to show volume flow and flow velocity, 85 … 250 V AC and sensor power supply | 527 320 |
| SCHMIDT® LED display MD 10.010, similar to 527 320 but with 24 V DC voltage supply | 528 240 |
| SCHMIDT® LED display MD 10.015, similar to 527 320 but with an additional sum function and a second measuring input | 527 330 |
| SCHMIDT® LED display MD 10.015, similar to 527 330 but with 24 V DC voltage supply | 528 250 |
| Technical data | |
|---|---|
| Measuring quantity | Standard flow velocity wN based on standard conditions 1) Temperature of medium TM |
| Measured medium | Air or nitrogen, other gases upon request |
| Measuring range wN | 0 … 40 / 60 / 90 m/s |
| Lower detection limit wN | 0.2 m/s |
| Measuring range TM | -20 … + 85 °C |
| Measuring accuracy | |
| Standard wN | ±(5 % of measured value + 0.4 % of fmr) 2) |
| High precision (optional) wN | ±(3 % of measured value + 0.4 % of fmr) 2) |
| Response time (t90) wN | 3 s (jump from 0 to 5 m/s) |
| Temperature gradient wN | ≤ 8 K/min (at wN = 5 m/s in air) |
| TM (wN > 2 m/s) | ±1 K (0 … 40 °C); ±2 K (in remaining measuring range) |
| Operating temperature | |
| Sensor probe | -20 … +85 °C |
| Electronics | -20 … +70 °C |
| Material | |
| Enclosure | PBT (glass-fibre reinforced) |
| Sensor tube | Stainless steel 1.4571 |
| Sensor head | Platinum element (glass passivated); PPO/PA |
| Compression fitting | Brass (G½) / stainless steel 1.4305 (R½) (order options) |
| Sensor cable | PVC |
| General data | |
| Humidity | Measuring mode: Non-condensing (< 95 % RH) |
| Operating pressure (max.) | 10 bar (overpressure) |
| Display | LED green: Operating state LED red (flashing): Sensor defective |
| Supply voltage | 24 V DC ± 10 % |
| Current consumption | Typ. < 40 mA, max. 60 mA |
| Analog outputs (wN and TM) | 4 … 20 mA (RL ≤ 300 Ω, CL ≤ 10 nF), short circuit protected |
| Electrical connection | Non-detachable cable , 4 x 0,14 mm2, length 5 m, with ferrules |
| Maximum cable length | 100 m (wire cross-section > 0,14 mm2 recommended) |
| Mounting position | Arbitrary (except in case of a downward flow and < 2 m/s at the same time) |
| Mounting tolerance | ±3° relative to flow direction (unidirectional) |
| Protection type | Sensor probe: IP66; enclosure: IP54 |
| Protection class | III (SELV or PELV) |
| Probe length L | 200/350 mm |
| Weight | 250 g (max.; L = 350 mm) |