Изберете език

SCHMIDT Flow Sensor SS 20.500

Производител: Schmidt
Product brochure (07/2025)
Instructions for Use (523375.02H)
Instructions for ATEX (526488.02G)
Type examination certificate ATEX (valid as of 03/2021)
3D-STP data
EU-Declaration of conformity (01/2024)
UK-Declaration of conformity (01/2024)
Type examination certificate ATEX (until 03/2021)

The solution for flow measurement – especially for dusty air and gases. High precision and compact!

  • ** NEW! Coating option "Parylene fully coated" ***
  • Dumb-bell head (independent of flow direction, easy to clean)
  • Flow and temperature signal
  • Probe length 100 … 1,000 mm (optional special length)
  • Remote sensor (optional)
  • Measuring ranges 0 … 1 m/s to 0 … 50 m/s
  • Coatings (optional)
  • Pressure resistant up to 10 bar
  • ATEX (optional):

- Gases, zone 2: II 3G Ex ec ic IIC T4 Gc

- Dust, zone 22: II 3D Ex tc ic IIIC T135°C Dc

To measure air and gas flows accurately and reproducibly, many parameters have to be correct. Therefore, the positioning of the sensor decisively determines the quality of the measurement results.

The gases to be measured also determine the choice of the right sensor. In safety-relevant areas such as the chemical industry the requirement for explosion protection has also to be considered which means that the selection of a suitable sensor is very limited.

  • Industrial processes
  • Cleanroom and Pharma
  • Ventilation and air conditioning

Accessories

Connection technology

DescriptionArticle-Number
Connection cable with coupler socket, 5-pin, length 5 m, open cable ends 523 565
Connection cable with coupler socket, 5-pin, selectable length (2 … 100 m; 1-m-steps), cable end sleeves, halogen free 523 566
Coupler socket, 5-pin, with screw type terminals for cable of ø = 4 … 6 mm 523 562
Power supply unit: output 24 V / 1A DC, supply voltage 115/230 V AC (strip terminal) 535 282

Mounting and fixing technology

DescriptionArticle-Number
Mounting flange, galvanized steel 301 048
Mounting flange, stainless steel 520 181
Compression fitting, stainless steel, G½, atmospheric pressure 532 160
Compression fitting, brass, G½, atmospheric pressure 517 206
Compression fitting, brass, G½, max. 10 bar, with protection against pressure losses 524 891
Compression fitting, stainless steel, G½, max. 10 bar, with protection against pressure losses 524 919
Welding sleeve, steel, G½, according to EN 10241, 5 pieces 524 916
Welding sleeve, stainless steel 1.4571, G½, according to EN 10241, 2 pieces 524 882
Assembly kit for pipe assembly suitable for MD 10.010/10.015 including pipe clamps and collar for adjustment to pipe diameter 531 394

Measured value display

DescriptionArticle-Number
LED display MD 10.010 in wall housing to show volume flow and flow velocity, 85 … 250 V AC and sensor power supply 527 320
LED display MD 10.010, similar to 527 320 but with 24 V DC voltage supply 528 240
LED display MD 10.015, similar to 527 320 but with additional sum function and second measuring input 527 330
LED display MD 10.015, similar to 527 330 but with 24 V DC voltage supply 528 250

Miscellaneous

DescriptionArticle-Number
Attachable protective clip for dumbbell head against mechanical influences, stainless steel 531 026
Attachable protective 2-wires-clip for protection against mechanical influences,
stainless steel, H2O2-resistant
559 124
Technical data
Measuring quantity Standard flow velocity wN based on standard conditions 1)
Temperature of medium TM
Measured medium Air or nitrogen, other gases on request
Measuring range wN 0 … 1 / 2.5 / 5 / 10 / 20 / 35 / 50 m/s
Lower detection limit wN 0.06 m/s
Measuring range TM -40 … +85 °C
Measuring accuracy
Standard wN ±(3 % of measured value + [0.4 % of fmr; min. 0.02 m/s]) 2)
High precision (optional) wN ±(1 % of measured value + [0.4 % of fmr; min. 0.02 m/s]) 2) (only for measuring range 0 … 1 m/s)
Response time (t90) wN 3 s (jump from 0 to 5 m/s in air)
Temperature gradient wN ≤ 2 K/min (at wN = 5 m/s in air)
TM (wN > 1 m/s) ±1 K (10 … 30 °C); ±2 K (remaining measuring range)
Operating temperature
Sensor probe -40 … +85 °C
Electronics -20 … +70 °C
Storage temperature -40 … +85 °C
Material
Enclosure Aluminium, anodised
Sensor tube Stainless steel 1.4404
Sensor head PBT (glass-fibre reinforced), stainless steel 1.4404
Protective coating (optional) Polyurethane derivate (black, sensor head only) / parylene (transparent, sensor head only or "fully coated")
Protective sleeve (ATEX option) Aluminium, anodised
Sensor cable (of remote sensor) (TPE, halogenfree, black)
General data
Humidity Measuring mode: Non-condensing (< 95 % RH)
Operating pressure (max.) Compact version: 10 bar (overpressure)
Remote version: Atmospheric (700 hPa … 1,300 hPa)
Display 4 x Duo-LEDs (green/red/orange)
Supply voltage 24 V AC/DC ± 20 %
Current consumption Typ. < 60 mA (max. 170 mA)
Analog outputs
Type: Auto U / I)
wN, TM
0 … 10 V / 4 … 20 mA (switching of signal characteristic depends on RL)
-Voltage output (0 … 10 V): RL ≥ 550 Ω (short-circuit protected)
- Current output (4 … 20 mA): RL ≤ 500 Ω
- Change-over hysteresis: 50 Ω
- CL ≤ 10 nF
Electrical connection Plug-in connector M12 (A-coded), male, 5-pin, screwed
ATEX approval only in combination with suitable cable!
Maximum cable length Voltage interface / current interface: 100 m
Voltage mode: Use AGND and RL ≥ 10 k (mass offset)
Mounting position Arbitrary
Minimum immersion depth 58.5 mm (< 58.5 mm on request)
Protection type Sensor probe: IP67; enclosure: IP65; electrical connector: IP67 (with correctly attached cable)
Protection class III (SELV or PELV)
ATEX category Gas (zone 2): II 3G Ex ec ic IIC T4 Gc
Dust (zone 22): II 3D Ex tc ic IIIC T135°C Dc
Probe length Compact version: 100/150/350 mm; special length: >100 … 1000 mm (step: 10 mm)
Remote version: 161 mm (probe); cable length: 3 m or special length 1 … 30 m (step: 1 m)
Weight 400 g max. (without connecting cable)
Copyright MAXXmarketing GmbH