Select your language

SCHMIDT Flow Sensor SS 20.651

Manufacturer: Schmidt
Product brochure (04/2025)
Instructions for use SS 20.651 (547608.02D)
Fieldbus software
3D-STP data
EU-Declaration of conformity (01/2024)
UK-Declaration of conformity (01/2024)
Instructions for use PROFIBUS (543565.02B)
Instructions for use DeviceNet (557786.02)
  • Chamber head (fast response time)
  • Flow and temperature signal
  • Probe length 250 … 1,000 mm
  • Remote sensor (optional)
  • Measuring ranges 0 … 2.5 m/s to 0 … 60 m/s
  • Pulse output
  • Profi-BUS DP-V0 and DeviceNet (optional)
  • Pressure resistant up to 16 bar
  • Temperature range up to +350 °C

In many areas the measurement of flow velocity and/or volume flow at higher temperatures of up to +350 °C is very important in terms of energy efficiency, quantity detection and plant control.

Mechanically rugged, precise and long-term stable measurement values ​​as well as different installation sites

  • Burner control
  • Drying processes
  • Sterile tunnel
  • Combustion air
  • Process technology

Accessories

Connection technology

DescriptionArticle-Number
Connecting cable 8-pin with coupler socket, length 5 m, open cable ends 524 921
Coupler socket 8-pin with coupler socket, cable length selectable, (2 … 100 m; 1 m steps), cable end sleeves, free of halogen 524 942
Coupler socket 8-pin, with screw connections for cable ø 6 ... 8 mm 524 929
Power supply unit: output 24 V / 1A DC, supply voltage 115/230 V AC (strip terminal) 535 282

Mounting and fixing technology

DescriptionArticle-Number
Compression fitting SS 20.651 HT-p = 350 °C 525 734
Welding sleeve, steel, G½, according to EN 10241, 5 pieces 524 916
Welding sleeve,stainless steel 1.4571, G½, according to EN 10241, 2 pieces 524 882
Assembly kit for pipe assembly suitable for MD 10.010/10.015, including pipe clamps and collar for adjustment to pipe diameter 531 394

Measured value display

DescriptionArticle-Number
LED display MD 10.010 in wall housing to show volume flow and flow velocity, 85 … 250 V AC and sensor power supply 527 320
LED display MD 10.010, similar to 527 320 but with 24 V DC voltage supply 528 240
LED display MD 10.015, similar to 527 320 but with additional sum function and second measuring input 527 330
LED display MD 10.015, similar to 527 330 but with 24 V DC voltage supply 528 250
Technical data
Measuring quantity Standard flow velocity wN based on standard conditions 1)
Medium temperature TM
Measured medium Clean air or nitrogen, other gases upon request
Measuring range wN 0 … 10 / 20 / 40 / 60 m/s
Lower detection limit wN 0.2 m/s (at TM = 20 °C)
Measuring range TM 0 … +200/+350 °C
Operating temperature
Sensor head 0 … +200/+350 °C
Electronics -20 … +70 °C
Storage temperature -20 … +85 °C
Material
Housing Aluminium, anodised
Sensor tube Stainless steel 1.4571
Sensor head Platinum element (glass-passivated), ceramics
Compression fitting Stainless steel 1.4571 or brass (depending on sensor option)
Measuring accuracy
Standard wN ±(3 % of measured value + [0.4 % of fmr; min. 0.08 m/s]) 2)
High precision (optional) wN ±(1 % of measured value + [0.4 % of fmr; min. 0.08 m/s]) 2)
Response time (t90) wN 3 s (jump of wN from 0 to 5 m/s in air)
Temperature gradient wN < 8 K/min (at wN = 5 m/s in air)
Temperature TM (wN > 2 m/s) ±2 K (TM = 10 ... 30 °C); ±4 K (remaining measuring range)
Recovery time wN < 10 s (after temperature change of ∆ϑ = 40 K and at wN = 5 m/s in air)
General data
Humidity Measuring mode: Non-condensing (< 95 % RH); high relative air humidity in combination with high temperature can cause measurement deviations
Operating pressure (max.) Atmospheric (700 … 1,300 hPa) / 16 bar (optional; over pressure)
Display 4 x Duo-LEDs (green/red/orange)
Supply voltage 24 V DC ± 20 %
Current consumption Typ. 50 mA (without pulse outputs); max. 250 mA (including signal currents of all outputs)
Start up time Approx. 10 s after switch-on
Analog outputs
Type: Auto U / I)
wN, TM
0 … 10 V / 4 … 20 mA (switching of signal characteristic depends on RL)
-Voltage output (0 … 10 V): RL ≥ 550 Ω (short-circuit protected)
- Current output (4 … 20 mA): RL ≤ 500 Ω
- Change-over hysteresis: 50 Ω
- CL ≤ 10 nF
Pulse outputs: Signalization Standard: Frequency f ~ wN
f = 0 … fmax
fmax = 100 Hz (option: fmax = 10 … 99 Hz)
Optional: Pulse quantity:
1 pulse/1 m3; 1 pulse/0.1 m3; 1 pulse/0.01 m3 (max. 100 pulses/s)
Pulse outputs: Technology 1. Highside-driver (PNP, open collector) at protected supply voltage; not galvanically isolated)
Short-circuit protected (analog): 100 mA
High level: > supply voltage - 3 V
Leckage current: IOFF < 10 µA
2. Semiconductor relay; output galvanically isolated
Output voltage/current: Max. 30 V / 50 mA
Fieldbus (optional) Profibus DP / DeviceNet
Electrical connection Plug-in connector M12 (A-coded), male, 8-pole (shielded), screwed
Maximum cable length Voltage interface / current interface / pulse outputs: 100 m
Voltage mode: Use AGND and RL ≥ 10 k (mass offset)
Mounting position Arbitrary (atmospheric; under higher pressure preferred horizontally)
Mounting tolerance ±3° relative to flow direction (unidirectional)
Minimum immersion depth DN25 ( also more, depending on the temperature of medium)
Power-up time 10 s (after switching-on)
Protection type Sensor probe: IP54; enclosure: IP65; electrical connector: IP67 (with correctly attached cable)
Protection class III (SELV or PELV)
Probe length 250/400/600/1,000 mm (for both versions: compact and remote probe)
Cable length (remote version) Selectable: 1 … 10 m (step: 1 m)
Weight 550 g max. (400 mm probe length) / 750 g (field bus version)
Copyright MAXXmarketing GmbH
JoomShopping Download & Support